Clínic Barcelona. Hospital Universitari

Test catalog

Back to Catalog

Anti-Ro52 antibodies, serum

Fee code: 54031

Physician:

Odette Viñas Gomis, Estíbaliz Ruiz Ortiz de Arizabaleta

Laboratory:

> Immunology Department

Method description

Enzyme Immunoassay

Delivery time

30 days

Note to delivery time

Requisites

Attach medical history summary, established diagnosis or suspicion and the reason for the request. To study anti-Ro60 antibodies request anti-Ro and anti-La in serum

Specimen type

Serum

Specimen volume

0,5 mL

Specimen minimum volume

0,2 mL

Collection instructions

8-hour fast

Preanalytic treatment

Centrifuge at 3000 rpm 10 minutes

Transport conditions

Refrigerated

Rejection criteria

Inadequate sample (blood with anticoagulant), Intense hemolysis

Results

Reference values

Values Units   Age  
IgG anti-Ro-52 Negative: < 15 U/mL    
IgG anti-Ro-52 Doubtful: 15 to 25 U/mL    
IgG anti-Ro-52 Positive: > 25 U/mL    

The information in this document may be obsolete after printing. The current version is on the web.

Biomedical Diagnostic Center (CDB)

Villarroel, 170 · 08036 Barcelona
Tel: +34 93 227 54 64 · Fax: +34 93 227 98 75 · · www.hospitalclinic.org